Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Kyobu Geka ; 77(2): 101-105, 2024 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-38459858

RESUMO

A 75-year-old woman was diagnosed with type B acute aortic dissection 14 years ago and 3-channeled aortic dissection 7 years ago. She received total arch replacement 6 years ago and descending aortic replacement with double barrel anastomosis technique for distal anastomosis 5 years ago. Computed tomography( CT) revealed giant thyroid tumor and thoracoabdominal aortic aneurysm( 58 mm in diameter). She suffered from back pain during her follow-up period. CT revealed ruptured thoracoabdominal aortic aneurysm. First, the false lumen of descending aorta was closed by thoracic endovascular aortic repair, and then thoracoabdominal aortic replacement was performed uneventfully.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma da Aorta Toracoabdominal , Dissecção Aórtica , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Anastomose Cirúrgica , Resultado do Tratamento
2.
J Endovasc Ther ; : 15266028231215204, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041256

RESUMO

CLINICAL IMPACT: We developed a novel Endovascular aortic repair technique for internal iliac artery preservation using a physician modified Endurant contralateral limb. This procedure was safe and reliable for preserving internal iliac artery flow in 24 patients with common and internal iliac artery aneurysms. We believe that our technique has the potential to expand the anatomic indications for internal iliac artery preserving procedures.

3.
Kyobu Geka ; 76(11): 941-944, 2023 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-38056952

RESUMO

An 85-year-old woman underwent aortic arch replacement and thoracic endovascular aortic repair (TEVAR) 5 years ago. She suffered from chest and back pain. Computed tomography (CT) demonstrated enlargement of the aortic aneurysm by a type Ⅲb endoleak. TEVAR was performed to close a type Ⅲb endoleak with a relining technique uneventfully. Intraoperative completion aortography and postoperative CT confirmed the disappearance of a type Ⅲb endoleak. She was discharged 27 days after the treatment.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Feminino , Humanos , Idoso de 80 Anos ou mais , Prótese Vascular , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Correção Endovascular de Aneurisma , Stents , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Estudos Retrospectivos
4.
Kyobu Geka ; 76(12): 1025-1029, 2023 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-38057981

RESUMO

An 82-year-old woman suddenly developed chest pain and apoplexy. Computed tomography (CT) showed acute type A aortic dissection, the true lumen in the brachicephalic artery was severely compressed by the faulse lumen. Pulsation in the either leg was not detected during induction of anesthesia. We evaluated the cerebral blood flow and lower extremity blood flow using near infrared spectroscopy (NIRS) during the operation, tissue oxygenation index (TOI) was continuously monitored during the operation. Cardiopulmonary bypass( CPB) was established by puncturing the true lumen in the ascending aorta and bicaval venous drainage. TOI was returned to normal range by CPB. Although the central repair (ascending aorta replacement) was performed, leg ischemia persisted. We performed ascending aorta-bifemoral bypass. After the operation, leg ischemia disappeared and CT revealed patency of the bypass graft. Postoperative course was uneventful without deterioration of neurological function. She was discharged 49 days after the operation.


Assuntos
Dissecção Aórtica , Perna (Membro) , Feminino , Humanos , Idoso de 80 Anos ou mais , Perna (Membro)/irrigação sanguínea , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/cirurgia , Extremidade Inferior/cirurgia
5.
Kyobu Geka ; 76(13): 1127-1130, 2023 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-38088078

RESUMO

An 97-year-old woman was diagnosed with complete atrioventricular block and underwent pacemaker implantation( PMI). Three days after the PMI, computed tomography revealed cardiac perforation and migration of the lead to the abdominal cavity. Surgical procedure through median sternotomy was performed, and the penetrated lead was removed. The holes of the right ventricle and diaphragm were repaired. Abdominal organ was not injured. She was discharged 14 days after the surgical procedure.


Assuntos
Traumatismos Cardíacos , Marca-Passo Artificial , Feminino , Humanos , Idoso de 80 Anos ou mais , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Diafragma/diagnóstico por imagem , Diafragma/cirurgia , Marca-Passo Artificial/efeitos adversos , Tórax , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/cirurgia
6.
J Craniofac Surg ; 24(6): e588-90, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24220473

RESUMO

A large full-thickness defect of the lower lip is difficult to reconstruct. Preservation of eating and speaking functions based on maintenance of oral sphincter and muscle function, sensation, and the oral aperture are the basic aims. It is also important to achieve a good aesthetic appearance. Here, we describe a new procedure using combined bilateral hatchet and nasolabial advancement flaps for a large full-thickness defect of the lower lip. The aim of use of the hatchet flap is to make a natural curve from the mentolabial fold to the mental protuberance using the "dog ear" resulting from suturing medially advanced bilateral hatchet flaps and to preserve a more certain blood supply to the medial edge of the flap. Our results indicate that the procedure using combined bilateral hatchet flaps and nasolabial flaps is useful for a U-shaped large full-thickness defect, with good functional and aesthetic outcomes.


Assuntos
Carcinoma de Células Escamosas/cirurgia , Neoplasias Labiais/cirurgia , Lábio/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Transplante de Pele/métodos , Retalhos Cirúrgicos/transplante , Ingestão de Alimentos/fisiologia , Estética , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sensação/fisiologia , Fala/fisiologia , Retalhos Cirúrgicos/irrigação sanguínea , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...